| 图片 | 厂商料号 | 库存情况 | 价格 | 数量 | 数据表 | 系列 | 包装 | 产品状态 | 输入类型 | 输出数量 | 直流电压 - 输入(最小值) | 直流电压 - 输入(最大值) | 电压 - 输出 1 | 效率 | 电压 - 输出 2 | 电压 - 输出 3 | 交流电压 - 输入 | 电压 - 输出 4 | 电压 - 输出 5 | 应用 | 电压 - 输出 6 | 工作温度 | 电压 - 隔离 | 电流 - 输出(最大值) | 功率(瓦特) | 特性 | 认证机构 | 标准编号 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ECB40W18-72S54-EDRT+ FBL 127ISOLATED DC/DC CONVERTERS 40W 8. Cincon Electronics Co. LTD |
0 | - |
|
数据表 |
ECB40W18 (40W) | Bulk | Active | DC | 1 | 10V | 160V | 54V | 88% | - | - | - | - | - | ITE (Commercial), Railway | - | -40°C ~ 95°C (With Derating) | 3 kV | 740mA | 40W | Adjustable Output, Baseplate, Heat Sink, Remote On/Off | CE, UKCA | 50155; 62368-1 |
|
ECB40W18-72S24-EDRTP+ FBL 127ISOLATED DC/DC CONVERTERS 40W 8. Cincon Electronics Co. LTD |
0 | - |
|
数据表 |
ECB40W18 (40W) | Bulk | Active | DC | 1 | 10V | 160V | 24V | 88% | - | - | - | - | - | ITE (Commercial), Railway | - | -40°C ~ 95°C (With Derating) | 3 kV | 1.666A | 40W | Adjustable Output, Baseplate, Heat Sink, Remote On/Off | CE, UKCA | 50155; 62368-1 |
|
ECB40W18-72S12-EDRTPISOLATED DC/DC CONVERTERS 40W 8. Cincon Electronics Co. LTD |
0 | - |
|
数据表 |
ECB40W18 (40W) | Bulk | Active | DC | 1 | 10V | 160V | 12V | 89% | - | - | - | - | - | ITE (Commercial), Railway | - | -40°C ~ 95°C (With Derating) | 3 kV | 3.333A | 40W | Adjustable Output, Baseplate, Remote On/Off | CE, UKCA | 50155; 62368-1 |
|
ECB40W18-72S54-EDRTP+ FBL 127ISOLATED DC/DC CONVERTERS 40W 8. Cincon Electronics Co. LTD |
0 | - |
|
数据表 |
ECB40W18 (40W) | Bulk | Active | DC | 1 | 10V | 160V | 54V | 88% | - | - | - | - | - | ITE (Commercial), Railway | - | -40°C ~ 95°C (With Derating) | 3 kV | 740mA | 40W | Adjustable Output, Baseplate, Heat Sink, Remote On/Off | CE, UKCA | 50155; 62368-1 |
|
ECB40W18-72S24-EDRT+ FBL 127ISOLATED DC/DC CONVERTERS 40W 8. Cincon Electronics Co. LTD |
0 | - |
|
数据表 |
ECB40W18 (40W) | Bulk | Active | DC | 1 | 10V | 160V | 24V | 88% | - | - | - | - | - | ITE (Commercial), Railway | - | -40°C ~ 95°C (With Derating) | 3 kV | 1.666A | 40W | Adjustable Output, Baseplate, Heat Sink, Remote On/Off | CE, UKCA | 50155; 62368-1 |
|
ECB40W18-72S15-EDRTPISOLATED DC/DC CONVERTERS 40W 8. Cincon Electronics Co. LTD |
0 | - |
|
数据表 |
ECB40W18 (40W) | Bulk | Active | DC | 1 | 10V | 160V | 15V | 87.5% | - | - | - | - | - | ITE (Commercial), Railway | - | -40°C ~ 95°C (With Derating) | 3 kV | 2.666A | 40W | Adjustable Output, Baseplate, Remote On/Off | CE, UKCA | 50155; 62368-1 |
|
ECB40W18-72S15-EDRT+ FBL 127ISOLATED DC/DC CONVERTERS 40W 8. Cincon Electronics Co. LTD |
0 | - |
|
数据表 |
ECB40W18 (40W) | Bulk | Active | DC | 1 | 10V | 160V | 15V | 87.5% | - | - | - | - | - | ITE (Commercial), Railway | - | -40°C ~ 95°C (With Derating) | 3 kV | 2.666A | 40W | Adjustable Output, Baseplate, Heat Sink, Remote On/Off | CE, UKCA | 50155; 62368-1 |
|
ECB40W18-72S12-EDRTISOLATED DC/DC CONVERTERS 40W 8. Cincon Electronics Co. LTD |
0 | - |
|
数据表 |
ECB40W18 (40W) | Bulk | Active | DC | 1 | 10V | 160V | 12V | 89% | - | - | - | - | - | ITE (Commercial), Railway | - | -40°C ~ 95°C (With Derating) | 3 kV | 3.333A | 40W | Adjustable Output, Baseplate, Remote On/Off | CE, UKCA | 50155; 62368-1 |
|
ECB40W18-72S12-EDRT+ FBL 127ISOLATED DC/DC CONVERTERS 40W 8. Cincon Electronics Co. LTD |
0 | - |
|
数据表 |
ECB40W18 (40W) | Bulk | Active | DC | 1 | 10V | 160V | 12V | 89% | - | - | - | - | - | ITE (Commercial), Railway | - | -40°C ~ 95°C (With Derating) | 3 kV | 3.333A | 40W | Adjustable Output, Baseplate, Heat Sink, Remote On/Off | CE, UKCA | 50155; 62368-1 |
|
CFM40C090-DRAC/DC DIN RAIL SUPPLY 9V 40W Cincon Electronics Co. LTD |
11 | - |
|
数据表 |
CFM40CXXX-DR (40W) | Box | Active | AC | 1 | - | - | 9V | 84% | - | - | 90 ~ 264 VAC | - | - | ITE (Commercial) | - | 0°C ~ 70°C (With Derating) | 4.242 kV | 4.45A | 40W | Universal Input | CE, cURus, FCC, TUV | - |