| 图片 | 厂商料号 | 库存情况 | 价格 | 数量 | 数据表 | 系列 | 封装/外壳 | 包装 | 产品状态 | 用于测量 | 传感器类型 | 通道数 | 输出 | 灵敏度 | 极化 | 频率 | 线性度 | 电流 - 传感 | 精度 | 电压 - 电源 | 认证 | 响应时间 | 安装类型 | 等级 | 电流 - 电源(最大值) | 工作温度 | 供应商设备封装 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
CASR 50-NPSENSOR CURRENT FLUX 50A AC/DC LEM USA Inc. |
0 | - |
|
数据表 |
CASR | Module | Tray | Active | AC/DC | Flux Gate, Closed Loop | 1 | Ratiometric, Voltage | 12.5mV/A | Bidirectional | 300kHz | ±1% | 50A | ±0.8% | 4.75V ~ 5.25V | - | 0.3µs | Through Hole | - | 20mA | -40°C ~ 85°C | - |
|
|
CAS 50-NPSENSOR CURRENT FLUX 50A AC/DC LEM USA Inc. |
0 | - |
|
数据表 |
CAS | Module | Tray | Active | AC/DC | Flux Gate, Closed Loop | 1 | Ratiometric, Voltage | 12.5mV/A | Bidirectional | 300kHz | ±1% | 50A | ±0.8% | 4.75V ~ 5.25V | - | 0.3µs | Through Hole | - | 20mA | -40°C ~ 85°C | - |
|
LAH 25-NPSENSOR CURRENT HALL 8A, 12A, 25A LEM USA Inc. |
0 | - |
|
数据表 |
LAH | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1 | Ratiometric, Current | - | Bidirectional | DC ~ 200kHz | ±0.2% | 8A, 12A, 25A (Selectable) | ±0.3% | ±12V ~ 15V | - | 0.5µs | Through Hole | - | 35mA | -25°C ~ 85°C | - |
|
|
HASS 400-SSENSOR CURRENT HALL 400A AC/DC LEM USA Inc. |
0 | - |
|
数据表 |
HASS | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Open Loop | 1 | Ratiometric, Voltage | - | Bidirectional | DC ~ 50kHz | ±0.5% | 400A | ±1% | 5V | - | 3µs | Through Hole | - | 19mA | -40°C ~ 85°C | - |
|
HTFS 200-PSENSOR CURRENT HALL 200A AC/DC LEM USA Inc. |
0 | - |
|
数据表 |
HTFS | Module | Tube | Active | AC/DC | Hall Effect, Open Loop | 1 | Ratiometric, Voltage | - | Bidirectional | DC ~ 240kHz | ±0.5% | 200A | ±1% | 5V | - | 3.5µs | Through Hole | - | 25mA | -40°C ~ 105°C | - |
|
HTFS 400-PSENSOR CURRENT HALL 400A AC/DC LEM USA Inc. |
0 | - |
|
数据表 |
HTFS | Module | Tube | Active | AC/DC | Hall Effect, Open Loop | 1 | Ratiometric, Voltage | - | Bidirectional | DC ~ 240kHz | ±0.5% | 400A | ±1% | 5V | - | 3.5µs | Through Hole | - | 25mA | -40°C ~ 105°C | - |
|
HY 25-PSENSOR CURRENT HALL 25A AC/DC LEM USA Inc. |
0 | - |
|
数据表 |
HY | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Open Loop | 1 | Ratiometric, Voltage | - | Bidirectional | DC ~ 50kHz | ±1% | 25A | ±1% | ±12V ~ 15V | - | 3µs | Through Hole | - | 10mA | -10°C ~ 80°C | - |
|
DHAB S/137SENSOR CURRENT 75A/1000A 2CH LEM USA Inc. |
0 | - |
|
数据表 |
DHAB | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 2 | Ratiometric, Voltage | 26.7mV/A | Unidirectional | 70Hz | ±0.5% | 75A, 1000A | ±2.5% | 4.75V ~ 5.25V | - | - | Through Hole | - | 20mA | -40°C ~ 125°C | - |
|
AT 5 B5SENSOR CURRENT XFMR 5A AC LEM USA Inc. |
0 | - |
|
数据表 |
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 0V ~ 5V | - | Bidirectional | 50/60Hz | ±0.5% | 5A | ±1.5% | Self Powered | - | 300ms | Chassis Mount | - | - | -20°C ~ 60°C | - |
|
AT 50 B10SENSOR CURRENT XFMR 50A AC LEM USA Inc. |
0 | - |
|
数据表 |
AT | Module | Bulk | Active | AC | Transformer w/Conditioning | 1 | Ratiometric, 0V ~ 10V | - | Bidirectional | 50/60Hz | ±0.5% | 50A | ±1.5% | Self Powered | - | 300ms | Chassis Mount | - | - | -20°C ~ 60°C | - |